2019 Subaru Forester
Mileage
99,166
Service Date
6/13/2024
Services Performed
- AC was empty. need to perform evac and recharge, is a R1234YF system
- Install A/C gauges to check system pressures, compressor doesn't run or short cycles, found pressure reading _0___ high side and __0__ low side, and cools to__ambient__. Evacuate system and it had __0__ oz of freon and the system requires _12___ oz. Recharge with freon and dye, recheck pressures, now reading __200__ high side and __30__ low side, cools to _42___. Dye light test to check for leaks and found __1__leaks at this time from the drivers side a/c line into the condenser, o-ring is leaking
- Remove line at condenser, replaced o-ring on the line, reinstall and needs recharge
- Install A/C gauges to check system pressures, compressor doesn't run or short cycles, found pressure reading __–__ high side and ___–_ low side, and cools to__–__. Evacuate system and it had __0__ oz of freon and the system requires __16__ oz. Recharge with freon and dye, recheck pressures, now reading __206__ high side and __30__ low side, cools to _42___. Dye light test to check for leaks and found __no__leaks at this time, will want to recheck is system stops blowing cold air
Shane B. gave our service a 5 star review on 6/23/2024